aboutsummaryrefslogtreecommitdiff
path: root/qga/commands-win32.c
diff options
context:
space:
mode:
Diffstat (limited to 'qga/commands-win32.c')
-rw-r--r--qga/commands-win32.c45
1 files changed, 27 insertions, 18 deletions
diff --git a/qga/commands-win32.c b/qga/commands-win32.c
index 1a21aac5ad..1e91aa2343 100644
--- a/qga/commands-win32.c
+++ b/qga/commands-win32.c
@@ -613,25 +613,28 @@ out:
return pci;
}
-static int get_disk_bus_type(HANDLE vol_h, Error **errp)
+static void get_disk_properties(HANDLE vol_h, GuestDiskAddress *disk,
+ Error **errp)
{
STORAGE_PROPERTY_QUERY query;
STORAGE_DEVICE_DESCRIPTOR *dev_desc, buf;
DWORD received;
+ ULONG size = sizeof(buf);
dev_desc = &buf;
- dev_desc->Size = sizeof(buf);
query.PropertyId = StorageDeviceProperty;
query.QueryType = PropertyStandardQuery;
if (!DeviceIoControl(vol_h, IOCTL_STORAGE_QUERY_PROPERTY, &query,
sizeof(STORAGE_PROPERTY_QUERY), dev_desc,
- dev_desc->Size, &received, NULL)) {
+ size, &received, NULL)) {
error_setg_win32(errp, GetLastError(), "failed to get bus type");
- return -1;
+ return;
}
+ disk->bus_type = find_bus_type(dev_desc->BusType);
+ g_debug("bus type %d", disk->bus_type);
- return dev_desc->BusType;
+ return;
}
/* VSS provider works with volumes, thus there is no difference if
@@ -643,7 +646,6 @@ static GuestDiskAddressList *build_guest_disk_info(char *guid, Error **errp)
GuestDiskAddress *disk;
SCSI_ADDRESS addr, *scsi_ad;
DWORD len;
- int bus;
HANDLE vol_h;
Error *local_err = NULL;
@@ -655,17 +657,16 @@ static GuestDiskAddressList *build_guest_disk_info(char *guid, Error **errp)
0, NULL);
if (vol_h == INVALID_HANDLE_VALUE) {
error_setg_win32(errp, GetLastError(), "failed to open volume");
- goto out_free;
+ goto err;
}
- g_debug("getting bus type");
- bus = get_disk_bus_type(vol_h, errp);
- if (bus < 0) {
- goto out_close;
+ disk = g_malloc0(sizeof(*disk));
+ get_disk_properties(vol_h, disk, &local_err);
+ if (local_err) {
+ error_propagate(errp, local_err);
+ goto err_close;
}
- disk = g_malloc0(sizeof(*disk));
- disk->bus_type = find_bus_type(bus);
g_debug("bus type %d", disk->bus_type);
/* always set pci_controller as required by schema. get_pci_info() should
* report -1 values for non-PCI buses rather than fail. fail the command
@@ -675,12 +676,14 @@ static GuestDiskAddressList *build_guest_disk_info(char *guid, Error **errp)
disk->pci_controller = get_pci_info(name, &local_err);
if (local_err) {
error_propagate(errp, local_err);
- goto out_close;
+ goto err_close;
}
- if (bus == BusTypeScsi || bus == BusTypeAta || bus == BusTypeRAID
+ if (disk->bus_type == GUEST_DISK_BUS_TYPE_SCSI
+ || disk->bus_type == GUEST_DISK_BUS_TYPE_IDE
+ || disk->bus_type == GUEST_DISK_BUS_TYPE_RAID
#if (_WIN32_WINNT >= 0x0600)
/* This bus type is not supported before Windows Server 2003 SP1 */
- || bus == BusTypeSas
+ || disk->bus_type == GUEST_DISK_BUS_TYPE_SAS
#endif
) {
/* We are able to use the same ioctls for different bus types
@@ -700,11 +703,17 @@ static GuestDiskAddressList *build_guest_disk_info(char *guid, Error **errp)
list = g_malloc0(sizeof(*list));
list->value = disk;
list->next = NULL;
-out_close:
CloseHandle(vol_h);
-out_free:
g_free(name);
return list;
+
+err_close:
+ g_free(disk);
+ CloseHandle(vol_h);
+err:
+ g_free(name);
+
+ return NULL;
}
#else