diff options
author | Halil Pasic <pasic@linux.vnet.ibm.com> | 2017-07-24 16:34:52 +0200 |
---|---|---|
committer | Cornelia Huck <cohuck@redhat.com> | 2017-07-25 09:17:42 +0200 |
commit | 7e01376daea75e888c370aab521a7d4aeaf2ffd1 (patch) | |
tree | a478d8d747f8569947f8e10b1bb902b66ca65486 /tests/prom-env-test.c | |
parent | b114588c069b64c5e1a0ec8534d487ee9f0e528a (diff) |
s390x/css: fix ilen in IO instruction handlers
When initiating a program check interruption by calling program_interrupt
the instruction length (ilen) of the current instruction is supplied as
the third parameter.
On s390x all the IO instructions are of instruction format S and their
ilen is 4. The calls to program_interrupt (introduced by commits
7b18aad543 ("s390: Add channel I/O instructions.", 2013-01-24) and
61bf0dcb2e ("s390x/ioinst: Add missing alignment checks for IO
instructions", 2013-06-21)) however use ilen == 2.
This is probably due to a confusion between ilen which specifies the
instruction length in bytes and ILC which does the same but in halfwords.
If kvm_enabled() this does not actually matter, because the ilen
parameter of program_interrupt is effectively unused.
Let's provide the correct ilen to program_interrupt.
Signed-off-by: Halil Pasic <pasic@linux.vnet.ibm.com>
Fixes: 7b18aad543 ("s390: Add channel I/O instructions.")
Fixes: 61bf0dcb2e ("s390x/ioinst: Add missing alignment checks for IO instructions")
Reviewed-by: David Hildenbrand <david@redhat.com>
Message-Id: <20170724143452.55534-1-pasic@linux.vnet.ibm.com>
Reviewed-by: Dong Jia Shi <bjsdjshi@linux.vnet.ibm.com>
Signed-off-by: Cornelia Huck <cohuck@redhat.com>