diff options
author | Cornelia Huck <cohuck@redhat.com> | 2020-01-28 18:37:27 +0100 |
---|---|---|
committer | Cornelia Huck <cohuck@redhat.com> | 2020-02-26 18:57:07 +0100 |
commit | 8f4335242a2ed7862363ff3bf08d0dfc3c3098e7 (patch) | |
tree | 8c9a5cd447c732957c48c41bf50d5a1c2c2c0fff /docs/system | |
parent | cc3d15a5ea960a65edbd1d6a3fb57e127f7a8080 (diff) |
docs: rstfy vfio-ap documentation
Move to system/, as this is mostly about configuring vfio-ap.
Message-Id: <20200213162942.14177-3-cohuck@redhat.com>
Reviewed-by: Pierre Morel <pmorel@linux.ibm.com>
Signed-off-by: Cornelia Huck <cohuck@redhat.com>
Diffstat (limited to 'docs/system')
-rw-r--r-- | docs/system/index.rst | 1 | ||||
-rw-r--r-- | docs/system/vfio-ap.rst | 916 |
2 files changed, 917 insertions, 0 deletions
diff --git a/docs/system/index.rst b/docs/system/index.rst index f66e6ea585..1a4b2c82ac 100644 --- a/docs/system/index.rst +++ b/docs/system/index.rst @@ -15,3 +15,4 @@ Contents: :maxdepth: 2 qemu-block-drivers + vfio-ap diff --git a/docs/system/vfio-ap.rst b/docs/system/vfio-ap.rst new file mode 100644 index 0000000000..3cd84179a2 --- /dev/null +++ b/docs/system/vfio-ap.rst @@ -0,0 +1,916 @@ +Adjunct Processor (AP) Device +============================= + +.. contents:: + +Introduction +------------ + +The IBM Adjunct Processor (AP) Cryptographic Facility is comprised +of three AP instructions and from 1 to 256 PCIe cryptographic adapter cards. +These AP devices provide cryptographic functions to all CPUs assigned to a +linux system running in an IBM Z system LPAR. + +On s390x, AP adapter cards are exposed via the AP bus. This document +describes how those cards may be made available to KVM guests using the +VFIO mediated device framework. + +AP Architectural Overview +------------------------- + +In order understand the terminology used in the rest of this document, let's +start with some definitions: + +* AP adapter + + An AP adapter is an IBM Z adapter card that can perform cryptographic + functions. There can be from 0 to 256 adapters assigned to an LPAR depending + on the machine model. Adapters assigned to the LPAR in which a linux host is + running will be available to the linux host. Each adapter is identified by a + number from 0 to 255; however, the maximum adapter number allowed is + determined by machine model. When installed, an AP adapter is accessed by + AP instructions executed by any CPU. + +* AP domain + + An adapter is partitioned into domains. Each domain can be thought of as + a set of hardware registers for processing AP instructions. An adapter can + hold up to 256 domains; however, the maximum domain number allowed is + determined by machine model. Each domain is identified by a number from 0 to + 255. Domains can be further classified into two types: + + * Usage domains are domains that can be accessed directly to process AP + commands + + * Control domains are domains that are accessed indirectly by AP + commands sent to a usage domain to control or change the domain; for + example, to set a secure private key for the domain. + +* AP Queue + + An AP queue is the means by which an AP command-request message is sent to an + AP usage domain inside a specific AP. An AP queue is identified by a tuple + comprised of an AP adapter ID (APID) and an AP queue index (APQI). The + APQI corresponds to a given usage domain number within the adapter. This tuple + forms an AP Queue Number (APQN) uniquely identifying an AP queue. AP + instructions include a field containing the APQN to identify the AP queue to + which the AP command-request message is to be sent for processing. + +* AP Instructions: + + There are three AP instructions: + + * NQAP: to enqueue an AP command-request message to a queue + * DQAP: to dequeue an AP command-reply message from a queue + * PQAP: to administer the queues + + AP instructions identify the domain that is targeted to process the AP + command; this must be one of the usage domains. An AP command may modify a + domain that is not one of the usage domains, but the modified domain + must be one of the control domains. + +Start Interpretive Execution (SIE) Instruction +---------------------------------------------- + +A KVM guest is started by executing the Start Interpretive Execution (SIE) +instruction. The SIE state description is a control block that contains the +state information for a KVM guest and is supplied as input to the SIE +instruction. The SIE state description contains a satellite control block called +the Crypto Control Block (CRYCB). The CRYCB contains three fields to identify +the adapters, usage domains and control domains assigned to the KVM guest: + +* The AP Mask (APM) field is a bit mask that identifies the AP adapters assigned + to the KVM guest. Each bit in the mask, from left to right, corresponds to + an APID from 0-255. If a bit is set, the corresponding adapter is valid for + use by the KVM guest. + +* The AP Queue Mask (AQM) field is a bit mask identifying the AP usage domains + assigned to the KVM guest. Each bit in the mask, from left to right, + corresponds to an AP queue index (APQI) from 0-255. If a bit is set, the + corresponding queue is valid for use by the KVM guest. + +* The AP Domain Mask field is a bit mask that identifies the AP control domains + assigned to the KVM guest. The ADM bit mask controls which domains can be + changed by an AP command-request message sent to a usage domain from the + guest. Each bit in the mask, from left to right, corresponds to a domain from + 0-255. If a bit is set, the corresponding domain can be modified by an AP + command-request message sent to a usage domain. + +If you recall from the description of an AP Queue, AP instructions include +an APQN to identify the AP adapter and AP queue to which an AP command-request +message is to be sent (NQAP and PQAP instructions), or from which a +command-reply message is to be received (DQAP instruction). The validity of an +APQN is defined by the matrix calculated from the APM and AQM; it is the +cross product of all assigned adapter numbers (APM) with all assigned queue +indexes (AQM). For example, if adapters 1 and 2 and usage domains 5 and 6 are +assigned to a guest, the APQNs (1,5), (1,6), (2,5) and (2,6) will be valid for +the guest. + +The APQNs can provide secure key functionality - i.e., a private key is stored +on the adapter card for each of its domains - so each APQN must be assigned to +at most one guest or the linux host. + +Example 1: Valid configuration +~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ + ++----------+--------+--------+ +| | Guest1 | Guest2 | ++==========+========+========+ +| adapters | 1, 2 | 1, 2 | ++----------+--------+--------+ +| domains | 5, 6 | 7 | ++----------+--------+--------+ + +This is valid because both guests have a unique set of APQNs: + +* Guest1 has APQNs (1,5), (1,6), (2,5) and (2,6); +* Guest2 has APQNs (1,7) and (2,7). + +Example 2: Valid configuration +~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ + ++----------+--------+--------+ +| | Guest1 | Guest2 | ++==========+========+========+ +| adapters | 1, 2 | 3, 4 | ++----------+--------+--------+ +| domains | 5, 6 | 5, 6 | ++----------+--------+--------+ + +This is also valid because both guests have a unique set of APQNs: + +* Guest1 has APQNs (1,5), (1,6), (2,5), (2,6); +* Guest2 has APQNs (3,5), (3,6), (4,5), (4,6) + +Example 3: Invalid configuration +~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ + ++----------+--------+--------+ +| | Guest1 | Guest2 | ++==========+========+========+ +| adapters | 1, 2 | 1 | ++----------+--------+--------+ +| domains | 5, 6 | 6, 7 | ++----------+--------+--------+ + +This is an invalid configuration because both guests have access to +APQN (1,6). + +AP Matrix Configuration on Linux Host +------------------------------------- + +A linux system is a guest of the LPAR in which it is running and has access to +the AP resources configured for the LPAR. The LPAR's AP matrix is +configured via its Activation Profile which can be edited on the HMC. When the +linux system is started, the AP bus will detect the AP devices assigned to the +LPAR and create the following in sysfs:: + + /sys/bus/ap + ... [devices] + ...... xx.yyyy + ...... ... + ...... cardxx + ...... ... + +Where: + +``cardxx`` + is AP adapter number xx (in hex) + +``xx.yyyy`` + is an APQN with xx specifying the APID and yyyy specifying the APQI + +For example, if AP adapters 5 and 6 and domains 4, 71 (0x47), 171 (0xab) and +255 (0xff) are configured for the LPAR, the sysfs representation on the linux +host system would look like this:: + + /sys/bus/ap + ... [devices] + ...... 05.0004 + ...... 05.0047 + ...... 05.00ab + ...... 05.00ff + ...... 06.0004 + ...... 06.0047 + ...... 06.00ab + ...... 06.00ff + ...... card05 + ...... card06 + +A set of default device drivers are also created to control each type of AP +device that can be assigned to the LPAR on which a linux host is running:: + + /sys/bus/ap + ... [drivers] + ...... [cex2acard] for Crypto Express 2/3 accelerator cards + ...... [cex2aqueue] for AP queues served by Crypto Express 2/3 + accelerator cards + ...... [cex4card] for Crypto Express 4/5/6 accelerator and coprocessor + cards + ...... [cex4queue] for AP queues served by Crypto Express 4/5/6 + accelerator and coprocessor cards + ...... [pcixcccard] for Crypto Express 2/3 coprocessor cards + ...... [pcixccqueue] for AP queues served by Crypto Express 2/3 + coprocessor cards + +Binding AP devices to device drivers +~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ + +There are two sysfs files that specify bitmasks marking a subset of the APQN +range as 'usable by the default AP queue device drivers' or 'not usable by the +default device drivers' and thus available for use by the alternate device +driver(s). The sysfs locations of the masks are:: + + /sys/bus/ap/apmask + /sys/bus/ap/aqmask + +The ``apmask`` is a 256-bit mask that identifies a set of AP adapter IDs +(APID). Each bit in the mask, from left to right (i.e., from most significant +to least significant bit in big endian order), corresponds to an APID from +0-255. If a bit is set, the APID is marked as usable only by the default AP +queue device drivers; otherwise, the APID is usable by the vfio_ap +device driver. + +The ``aqmask`` is a 256-bit mask that identifies a set of AP queue indexes +(APQI). Each bit in the mask, from left to right (i.e., from most significant +to least significant bit in big endian order), corresponds to an APQI from +0-255. If a bit is set, the APQI is marked as usable only by the default AP +queue device drivers; otherwise, the APQI is usable by the vfio_ap device +driver. + +Take, for example, the following mask:: + + 0x7dffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffff + +It indicates: + + 1, 2, 3, 4, 5, and 7-255 belong to the default drivers' pool, and 0 and 6 + belong to the vfio_ap device driver's pool. + +The APQN of each AP queue device assigned to the linux host is checked by the +AP bus against the set of APQNs derived from the cross product of APIDs +and APQIs marked as usable only by the default AP queue device drivers. If a +match is detected, only the default AP queue device drivers will be probed; +otherwise, the vfio_ap device driver will be probed. + +By default, the two masks are set to reserve all APQNs for use by the default +AP queue device drivers. There are two ways the default masks can be changed: + + 1. The sysfs mask files can be edited by echoing a string into the + respective sysfs mask file in one of two formats: + + * An absolute hex string starting with 0x - like "0x12345678" - sets + the mask. If the given string is shorter than the mask, it is padded + with 0s on the right; for example, specifying a mask value of 0x41 is + the same as specifying:: + + 0x4100000000000000000000000000000000000000000000000000000000000000 + + Keep in mind that the mask reads from left to right (i.e., most + significant to least significant bit in big endian order), so the mask + above identifies device numbers 1 and 7 (``01000001``). + + If the string is longer than the mask, the operation is terminated with + an error (EINVAL). + + * Individual bits in the mask can be switched on and off by specifying + each bit number to be switched in a comma separated list. Each bit + number string must be prepended with a (``+``) or minus (``-``) to indicate + the corresponding bit is to be switched on (``+``) or off (``-``). Some + valid values are:: + + "+0" switches bit 0 on + "-13" switches bit 13 off + "+0x41" switches bit 65 on + "-0xff" switches bit 255 off + + The following example:: + + +0,-6,+0x47,-0xf0 + + Switches bits 0 and 71 (0x47) on + Switches bits 6 and 240 (0xf0) off + + Note that the bits not specified in the list remain as they were before + the operation. + + 2. The masks can also be changed at boot time via parameters on the kernel + command line like this:: + + ap.apmask=0xffff ap.aqmask=0x40 + + This would create the following masks: + + apmask:: + + 0xffff000000000000000000000000000000000000000000000000000000000000 + + aqmask:: + + 0x4000000000000000000000000000000000000000000000000000000000000000 + + Resulting in these two pools:: + + default drivers pool: adapter 0-15, domain 1 + alternate drivers pool: adapter 16-255, domains 0, 2-255 + +Configuring an AP matrix for a linux guest +~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ + +The sysfs interfaces for configuring an AP matrix for a guest are built on the +VFIO mediated device framework. To configure an AP matrix for a guest, a +mediated matrix device must first be created for the ``/sys/devices/vfio_ap/matrix`` +device. When the vfio_ap device driver is loaded, it registers with the VFIO +mediated device framework. When the driver registers, the sysfs interfaces for +creating mediated matrix devices is created:: + + /sys/devices + ... [vfio_ap] + ......[matrix] + ......... [mdev_supported_types] + ............ [vfio_ap-passthrough] + ............... create + ............... [devices] + +A mediated AP matrix device is created by writing a UUID to the attribute file +named ``create``, for example:: + + uuidgen > create + +or + +:: + + echo $uuid > create + +When a mediated AP matrix device is created, a sysfs directory named after +the UUID is created in the ``devices`` subdirectory:: + + /sys/devices + ... [vfio_ap] + ......[matrix] + ......... [mdev_supported_types] + ............ [vfio_ap-passthrough] + ............... create + ............... [devices] + .................. [$uuid] + +There will also be three sets of attribute files created in the mediated +matrix device's sysfs directory to configure an AP matrix for the +KVM guest:: + + /sys/devices + ... [vfio_ap] + ......[matrix] + ......... [mdev_supported_types] + ............ [vfio_ap-passthrough] + ............... create + ............... [devices] + .................. [$uuid] + ..................... assign_adapter + ..................... assign_control_domain + ..................... assign_domain + ..................... matrix + ..................... unassign_adapter + ..................... unassign_control_domain + ..................... unassign_domain + +``assign_adapter`` + To assign an AP adapter to the mediated matrix device, its APID is written + to the ``assign_adapter`` file. This may be done multiple times to assign more + than one adapter. The APID may be specified using conventional semantics + as a decimal, hexadecimal, or octal number. For example, to assign adapters + 4, 5 and 16 to a mediated matrix device in decimal, hexadecimal and octal + respectively:: + + echo 4 > assign_adapter + echo 0x5 > assign_adapter + echo 020 > assign_adapter + + In order to successfully assign an adapter: + + * The adapter number specified must represent a value from 0 up to the + maximum adapter number allowed by the machine model. If an adapter number + higher than the maximum is specified, the operation will terminate with + an error (ENODEV). + + * All APQNs that can be derived from the adapter ID being assigned and the + IDs of the previously assigned domains must be bound to the vfio_ap device + driver. If no domains have yet been assigned, then there must be at least + one APQN with the specified APID bound to the vfio_ap driver. If no such + APQNs are bound to the driver, the operation will terminate with an + error (EADDRNOTAVAIL). + + * No APQN that can be derived from the adapter ID and the IDs of the + previously assigned domains can be assigned to another mediated matrix + device. If an APQN is assigned to another mediated matrix device, the + operation will terminate with an error (EADDRINUSE). + +``unassign_adapter`` + To unassign an AP adapter, its APID is written to the ``unassign_adapter`` + file. This may also be done multiple times to unassign more than one adapter. + +``assign_domain`` + To assign a usage domain, the domain number is written into the + ``assign_domain`` file. This may be done multiple times to assign more than one + usage domain. The domain number is specified using conventional semantics as + a decimal, hexadecimal, or octal number. For example, to assign usage domains + 4, 8, and 71 to a mediated matrix device in decimal, hexadecimal and octal + respectively:: + + echo 4 > assign_domain + echo 0x8 > assign_domain + echo 0107 > assign_domain + + In order to successfully assign a domain: + + * The domain number specified must represent a value from 0 up to the + maximum domain number allowed by the machine model. If a domain number + higher than the maximum is specified, the operation will terminate with + an error (ENODEV). + + * All APQNs that can be derived from the domain ID being assigned and the IDs + of the previously assigned adapters must be bound to the vfio_ap device + driver. If no domains have yet been assigned, then there must be at least + one APQN with the specified APQI bound to the vfio_ap driver. If no such + APQNs are bound to the driver, the operation will terminate with an + error (EADDRNOTAVAIL). + + * No APQN that can be derived from the domain ID being assigned and the IDs + of the previously assigned adapters can be assigned to another mediated + matrix device. If an APQN is assigned to another mediated matrix device, + the operation will terminate with an error (EADDRINUSE). + +``unassign_domain`` + To unassign a usage domain, the domain number is written into the + ``unassign_domain`` file. This may be done multiple times to unassign more than + one usage domain. + +``assign_control_domain`` + To assign a control domain, the domain number is written into the + ``assign_control_domain`` file. This may be done multiple times to + assign more than one control domain. The domain number may be specified using + conventional semantics as a decimal, hexadecimal, or octal number. For + example, to assign control domains 4, 8, and 71 to a mediated matrix device + in decimal, hexadecimal and octal respectively:: + + echo 4 > assign_domain + echo 0x8 > assign_domain + echo 0107 > assign_domain + + In order to successfully assign a control domain, the domain number + specified must represent a value from 0 up to the maximum domain number + allowed by the machine model. If a control domain number higher than the + maximum is specified, the operation will terminate with an error (ENODEV). + +``unassign_control_domain`` + To unassign a control domain, the domain number is written into the + ``unassign_domain`` file. This may be done multiple times to unassign more than + one control domain. + +Notes: No changes to the AP matrix will be allowed while a guest using +the mediated matrix device is running. Attempts to assign an adapter, +domain or control domain will be rejected and an error (EBUSY) returned. + +Starting a Linux Guest Configured with an AP Matrix +~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ + +To provide a mediated matrix device for use by a guest, the following option +must be specified on the QEMU command line:: + + -device vfio_ap,sysfsdev=$path-to-mdev + +The sysfsdev parameter specifies the path to the mediated matrix device. +There are a number of ways to specify this path:: + + /sys/devices/vfio_ap/matrix/$uuid + /sys/bus/mdev/devices/$uuid + /sys/bus/mdev/drivers/vfio_mdev/$uuid + /sys/devices/vfio_ap/matrix/mdev_supported_types/vfio_ap-passthrough/devices/$uuid + +When the linux guest is started, the guest will open the mediated +matrix device's file descriptor to get information about the mediated matrix +device. The ``vfio_ap`` device driver will update the APM, AQM, and ADM fields in +the guest's CRYCB with the adapter, usage domain and control domains assigned +via the mediated matrix device's sysfs attribute files. Programs running on the +linux guest will then: + +1. Have direct access to the APQNs derived from the cross product of the AP + adapter numbers (APID) and queue indexes (APQI) specified in the APM and AQM + fields of the guests's CRYCB respectively. These APQNs identify the AP queues + that are valid for use by the guest; meaning, AP commands can be sent by the + guest to any of these queues for processing. + +2. Have authorization to process AP commands to change a control domain + identified in the ADM field of the guest's CRYCB. The AP command must be sent + to a valid APQN (see 1 above). + +CPU model features: + +Three CPU model features are available for controlling guest access to AP +facilities: + +1. AP facilities feature + + The AP facilities feature indicates that AP facilities are installed on the + guest. This feature will be exposed for use only if the AP facilities + are installed on the host system. The feature is s390-specific and is + represented as a parameter of the -cpu option on the QEMU command line:: + + qemu-system-s390x -cpu $model,ap=on|off + + Where: + + ``$model`` + is the CPU model defined for the guest (defaults to the model of + the host system if not specified). + + ``ap=on|off`` + indicates whether AP facilities are installed (on) or not + (off). The default for CPU models zEC12 or newer + is ``ap=on``. AP facilities must be installed on the guest if a + vfio-ap device (``-device vfio-ap,sysfsdev=$path``) is configured + for the guest, or the guest will fail to start. + +2. Query Configuration Information (QCI) facility + + The QCI facility is used by the AP bus running on the guest to query the + configuration of the AP facilities. This facility will be available + only if the QCI facility is installed on the host system. The feature is + s390-specific and is represented as a parameter of the -cpu option on the + QEMU command line:: + + qemu-system-s390x -cpu $model,apqci=on|off + + Where: + + ``$model`` + is the CPU model defined for the guest + + ``apqci=on|off`` + indicates whether the QCI facility is installed (on) or + not (off). The default for CPU models zEC12 or newer + is ``apqci=on``; for older models, QCI will not be installed. + + If QCI is installed (``apqci=on``) but AP facilities are not + (``ap=off``), an error message will be logged, but the guest + will be allowed to start. It makes no sense to have QCI + installed if the AP facilities are not; this is considered + an invalid configuration. + + If the QCI facility is not installed, APQNs with an APQI + greater than 15 will not be detected by the AP bus + running on the guest. + +3. Adjunct Process Facility Test (APFT) facility + + The APFT facility is used by the AP bus running on the guest to test the + AP facilities available for a given AP queue. This facility will be available + only if the APFT facility is installed on the host system. The feature is + s390-specific and is represented as a parameter of the -cpu option on the + QEMU command line:: + + qemu-system-s390x -cpu $model,apft=on|off + + Where: + + ``$model`` + is the CPU model defined for the guest (defaults to the model of + the host system if not specified). + + ``apft=on|off`` + indicates whether the APFT facility is installed (on) or + not (off). The default for CPU models zEC12 and + newer is ``apft=on`` for older models, APFT will not be + installed. + + If APFT is installed (``apft=on``) but AP facilities are not + (``ap=off``), an error message will be logged, but the guest + will be allowed to start. It makes no sense to have APFT + installed if the AP facilities are not; this is considered + an invalid configuration. + + It also makes no sense to turn APFT off because the AP bus + running on the guest will not detect CEX4 and newer devices + without it. Since only CEX4 and newer devices are supported + for guest usage, no AP devices can be made accessible to a + guest started without APFT installed. + +Hot plug a vfio-ap device into a running guest +~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ + +Only one vfio-ap device can be attached to the virtual machine's ap-bus, so a +vfio-ap device can be hot plugged if and only if no vfio-ap device is attached +to the bus already, whether via the QEMU command line or a prior hot plug +action. + +To hot plug a vfio-ap device, use the QEMU ``device_add`` command:: + + (qemu) device_add vfio-ap,sysfsdev="$path-to-mdev" + +Where the ``$path-to-mdev`` value specifies the absolute path to a mediated +device to which AP resources to be used by the guest have been assigned. + +Note that on Linux guests, the AP devices will be created in the +``/sys/bus/ap/devices`` directory when the AP bus subsequently performs its periodic +scan, so there may be a short delay before the AP devices are accessible on the +guest. + +The command will fail if: + +* A vfio-ap device has already been attached to the virtual machine's ap-bus. + +* The CPU model features for controlling guest access to AP facilities are not + enabled (see 'CPU model features' subsection in the previous section). + +Hot unplug a vfio-ap device from a running guest +~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ + +A vfio-ap device can be unplugged from a running KVM guest if a vfio-ap device +has been attached to the virtual machine's ap-bus via the QEMU command line +or a prior hot plug action. + +To hot unplug a vfio-ap device, use the QEMU ``device_del`` command:: + + (qemu) device_del vfio-ap,sysfsdev="$path-to-mdev" + +Where ``$path-to-mdev`` is the same as the path specified when the vfio-ap +device was attached to the virtual machine's ap-bus. + +On a Linux guest, the AP devices will be removed from the ``/sys/bus/ap/devices`` +directory on the guest when the AP bus subsequently performs its periodic scan, +so there may be a short delay before the AP devices are no longer accessible by +the guest. + +The command will fail if the ``$path-to-mdev`` specified on the ``device_del`` command +does not match the value specified when the vfio-ap device was attached to +the virtual machine's ap-bus. + +Example: Configure AP Matrices for Three Linux Guests +----------------------------------------------------- + +Let's now provide an example to illustrate how KVM guests may be given +access to AP facilities. For this example, we will show how to configure +three guests such that executing the lszcrypt command on the guests would +look like this: + +Guest1:: + + CARD.DOMAIN TYPE MODE + ------------------------------ + 05 CEX5C CCA-Coproc + 05.0004 CEX5C CCA-Coproc + 05.00ab CEX5C CCA-Coproc + 06 CEX5A Accelerator + 06.0004 CEX5A Accelerator + 06.00ab CEX5C CCA-Coproc + +Guest2:: + + CARD.DOMAIN TYPE MODE + ------------------------------ + 05 CEX5A Accelerator + 05.0047 CEX5A Accelerator + 05.00ff CEX5A Accelerator + +Guest3:: + + CARD.DOMAIN TYPE MODE + ------------------------------ + 06 CEX5A Accelerator + 06.0047 CEX5A Accelerator + 06.00ff CEX5A Accelerator + +These are the steps: + +1. Install the vfio_ap module on the linux host. The dependency chain for the + vfio_ap module is: + + * iommu + * s390 + * zcrypt + * vfio + * vfio_mdev + * vfio_mdev_device + * KVM + + To build the vfio_ap module, the kernel build must be configured with the + following Kconfig elements selected: + + * IOMMU_SUPPORT + * S390 + * ZCRYPT + * S390_AP_IOMMU + * VFIO + * VFIO_MDEV + * VFIO_MDEV_DEVICE + * KVM + + If using make menuconfig select the following to build the vfio_ap module:: + -> Device Drivers + -> IOMMU Hardware Support + select S390 AP IOMMU Support + -> VFIO Non-Privileged userspace driver framework + -> Mediated device driver framework + -> VFIO driver for Mediated devices + -> I/O subsystem + -> VFIO support for AP devices + +2. Secure the AP queues to be used by the three guests so that the host can not + access them. To secure the AP queues 05.0004, 05.0047, 05.00ab, 05.00ff, + 06.0004, 06.0047, 06.00ab, and 06.00ff for use by the vfio_ap device driver, + the corresponding APQNs must be removed from the default queue drivers pool + as follows:: + + echo -5,-6 > /sys/bus/ap/apmask + + echo -4,-0x47,-0xab,-0xff > /sys/bus/ap/aqmask + + This will result in AP queues 05.0004, 05.0047, 05.00ab, 05.00ff, 06.0004, + 06.0047, 06.00ab, and 06.00ff getting bound to the vfio_ap device driver. The + sysfs directory for the vfio_ap device driver will now contain symbolic links + to the AP queue devices bound to it:: + + /sys/bus/ap + ... [drivers] + ...... [vfio_ap] + ......... [05.0004] + ......... [05.0047] + ......... [05.00ab] + ......... [05.00ff] + ......... [06.0004] + ......... [06.0047] + ......... [06.00ab] + ......... [06.00ff] + + Keep in mind that only type 10 and newer adapters (i.e., CEX4 and later) + can be bound to the vfio_ap device driver. The reason for this is to + simplify the implementation by not needlessly complicating the design by + supporting older devices that will go out of service in the relatively near + future, and for which there are few older systems on which to test. + + The administrator, therefore, must take care to secure only AP queues that + can be bound to the vfio_ap device driver. The device type for a given AP + queue device can be read from the parent card's sysfs directory. For example, + to see the hardware type of the queue 05.0004:: + + cat /sys/bus/ap/devices/card05/hwtype + + The hwtype must be 10 or higher (CEX4 or newer) in order to be bound to the + vfio_ap device driver. + +3. Create the mediated devices needed to configure the AP matrixes for the + three guests and to provide an interface to the vfio_ap driver for + use by the guests:: + + /sys/devices/vfio_ap/matrix/ + ... [mdev_supported_types] + ...... [vfio_ap-passthrough] (passthrough mediated matrix device type) + ......... create + ......... [devices] + + To create the mediated devices for the three guests:: + + uuidgen > create + uuidgen > create + uuidgen > create + + or + + :: + + echo $uuid1 > create + echo $uuid2 > create + echo $uuid3 > create + + This will create three mediated devices in the [devices] subdirectory named + after the UUID used to create the mediated device. We'll call them $uuid1, + $uuid2 and $uuid3 and this is the sysfs directory structure after creation:: + + /sys/devices/vfio_ap/matrix/ + ... [mdev_supported_types] + ...... [vfio_ap-passthrough] + ......... [devices] + ............ [$uuid1] + ............... assign_adapter + ............... assign_control_domain + ............... assign_domain + ............... matrix + ............... unassign_adapter + ............... unassign_control_domain + ............... unassign_domain + + ............ [$uuid2] + ............... assign_adapter + ............... assign_control_domain + ............... assign_domain + ............... matrix + ............... unassign_adapter + ............... unassign_control_domain + ............... unassign_domain + + ............ [$uuid3] + ............... assign_adapter + ............... assign_control_domain + ............... assign_domain + ............... matrix + ............... unassign_adapter + ............... unassign_control_domain + ............... unassign_domain + +4. The administrator now needs to configure the matrixes for the mediated + devices $uuid1 (for Guest1), $uuid2 (for Guest2) and $uuid3 (for Guest3). + + This is how the matrix is configured for Guest1:: + + echo 5 > assign_adapter + echo 6 > assign_adapter + echo 4 > assign_domain + echo 0xab > assign_domain + + Control domains can similarly be assigned using the assign_control_domain + sysfs file. + + If a mistake is made configuring an adapter, domain or control domain, + you can use the ``unassign_xxx`` interfaces to unassign the adapter, domain or + control domain. + + To display the matrix configuration for Guest1:: + + cat matrix + + The output will display the APQNs in the format ``xx.yyyy``, where xx is + the adapter number and yyyy is the domain number. The output for Guest1 + will look like this:: + + 05.0004 + 05.00ab + 06.0004 + 06.00ab + + This is how the matrix is configured for Guest2:: + + echo 5 > assign_adapter + echo 0x47 > assign_domain + echo 0xff > assign_domain + + This is how the matrix is configured for Guest3:: + + echo 6 > assign_adapter + echo 0x47 > assign_domain + echo 0xff > assign_domain + +5. Start Guest1:: + + /usr/bin/qemu-system-s390x ... -cpu host,ap=on,apqci=on,apft=on -device vfio-ap,sysfsdev=/sys/devices/vfio_ap/matrix/$uuid1 ... + +7. Start Guest2:: + + /usr/bin/qemu-system-s390x ... -cpu host,ap=on,apqci=on,apft=on -device vfio-ap,sysfsdev=/sys/devices/vfio_ap/matrix/$uuid2 ... + +7. Start Guest3:: + + /usr/bin/qemu-system-s390x ... -cpu host,ap=on,apqci=on,apft=on -device vfio-ap,sysfsdev=/sys/devices/vfio_ap/matrix/$uuid3 ... + +When the guest is shut down, the mediated matrix devices may be removed. + +Using our example again, to remove the mediated matrix device $uuid1:: + + /sys/devices/vfio_ap/matrix/ + ... [mdev_supported_types] + ...... [vfio_ap-passthrough] + ......... [devices] + ............ [$uuid1] + ............... remove + + + echo 1 > remove + +This will remove all of the mdev matrix device's sysfs structures including +the mdev device itself. To recreate and reconfigure the mdev matrix device, +all of the steps starting with step 3 will have to be performed again. Note +that the remove will fail if a guest using the mdev is still running. + +It is not necessary to remove an mdev matrix device, but one may want to +remove it if no guest will use it during the remaining lifetime of the linux +host. If the mdev matrix device is removed, one may want to also reconfigure +the pool of adapters and queues reserved for use by the default drivers. + +Limitations +----------- + +* The KVM/kernel interfaces do not provide a way to prevent restoring an APQN + to the default drivers pool of a queue that is still assigned to a mediated + device in use by a guest. It is incumbent upon the administrator to + ensure there is no mediated device in use by a guest to which the APQN is + assigned lest the host be given access to the private data of the AP queue + device, such as a private key configured specifically for the guest. + +* Dynamically assigning AP resources to or unassigning AP resources from a + mediated matrix device - see `Configuring an AP matrix for a linux guest`_ + section above - while a running guest is using it is currently not supported. + +* Live guest migration is not supported for guests using AP devices. If a guest + is using AP devices, the vfio-ap device configured for the guest must be + unplugged before migrating the guest (see `Hot unplug a vfio-ap device from a + running guest`_ section above.) |